Powered by ECI's InterLink™
software, LeakProof is able to keep track of the following parameters:
• Unit Serial Number
• Unit Model Number
• Error Message for failed units
• Component Description
• Serial Number
• Component Model
• Pass/Fail Status
• Test Date
• Operator that tested unit
• Cycle Time
• Leak Detector Verification
• Evacuation Pressures and Times
• Helium Pressures and Fill Times
• Decay Parameters
• Vent Parameters
• Helium Sniff Time
LeakProof's software allows for flexible configurations. Convenient
drop-down menus allow administrators to configure the station to
pull information from an external bill of materials, for instance.
There is also a Manual I/O program. Its outputs let you control
the station manually for system maintenance and troubleshooting.
Back to LeakProof™ Helium Leak Detecting
System
|